Design values

  • Minimize the normalized energy of resonant tank, which is given by

    Etank=(LrILrPk2+CrVCrPk2)fr2VoIoMaxE_{tank}=\frac{(L_rI_{L_rPk}^2+C_rV_{C_rPk}^2)f_r}{2V_oI_{oMax}}

The reason for using the peak value rather than the instantaneous value is that the sizes of LrL_r and CrC_r depend on the peak current and peak voltage.

  1. Select RnR_n to minimize EtankE_{tank}, so Rn=0.1R_n=0.1
  1. set the current source II at IoMaxI_{oMax} as load and fsf_s at fsMinf_{sMin}. IoMax=1A, fsMin=10MHzI_{oMax}=1A,\ f_{sMin}=10MHz