Design values
-
Minimize the normalized energy of resonant tank, which is given by
Etank=2VoIoMax(LrILrPk2+CrVCrPk2)fr
The reason for using the peak value rather than the instantaneous value is that the sizes of Lr and Cr depend on the peak current and peak voltage.
- Select Rn to minimize Etank, so Rn=0.1
- set the current source I at IoMax as load and fs at fsMin. IoMax=1A, fsMin=10MHz